We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for Earthquake-resistant device.
ipros is IPROS GMS IPROS One of the largest technical database sites in Japan that collects information on.

Earthquake-resistant device Product List and Ranking from 5 Manufacturers, Suppliers and Companies

Last Updated: Aggregation Period:Nov 05, 2025~Dec 02, 2025
This ranking is based on the number of page views on our site.

Earthquake-resistant device Manufacturer, Suppliers and Company Rankings

Last Updated: Aggregation Period:Nov 05, 2025~Dec 02, 2025
This ranking is based on the number of page views on our site.

  1. 特許機器 Hyogo//Other manufacturing
  2. 富山電気ビルデイング Toyama//Industrial Electrical Equipment
  3. トーヨーコーポレーション 東京営業部 東京営業3課 Tokyo//Consumer Electronics
  4. 4 null/null
  5. 5 山善 Osaka//Trading company/Wholesale

Earthquake-resistant device Product ranking

Last Updated: Aggregation Period:Nov 05, 2025~Dec 02, 2025
This ranking is based on the number of page views on our site.

  1. [Earthquake Measures] Vibration-Damping Seismic Device for Transformers TTR 特許機器
  2. Seismic Isolation Device "N-GRIP (N-Grip) [for Equipment]" トーヨーコーポレーション 東京営業部 東京営業3課
  3. Current issues and proposed measures regarding displacement suppression at transformer terminal sections. 富山電気ビルデイング
  4. Seismic device for preventing the tipping of fixtures and shelves: 'N-Grip for Fixtures'
  5. 4 Seismic Isolation Device 'N-Grip' <For Fixtures and Equipment> [Yamazen TFS] 山善

Earthquake-resistant device Product List

1~11 item / All 11 items

Displayed results

[Earthquake Measures] Vibration-Damping Seismic Device for Transformers TTR

BCP measures: Earthquake resistance measures start with transformers! We will achieve disaster relief and disaster reduction measures.

As part of BCP measures, there are cases where generators are introduced or expanded, but if the transformer is damaged, it cannot supply power to the grid. We support business continuity through seismic measures for transformers. The special absorber at the top of the transformer significantly suppresses displacement caused by seismic motion. It does not compromise the effectiveness of the installed vibration isolation device. 【Features】 ■ Achieves efficient disaster reduction measures (damage reduction and early recovery) ■ Significantly suppresses displacement caused by seismic motion with the special absorber at the top of the transformer ■ No degradation of seismic performance even after experiencing more than 30 instances of swarm earthquake waves (experimentally verified) ■ Compatible with both molded transformers and oil-filled transformers ■ Does not compromise the effectiveness of the installed vibration isolation device *For more details, please refer to the PDF materials or feel free to contact us.

  • Anti-vibration, earthquake-proof, vibration-isolating devices
  • Transformers

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Seismic Isolation Device "N-GRIP (N-Grip) [for Equipment]"

Providing peace of mind and safety by protecting people and equipment from earthquakes! A seismic device that can be reused repeatedly with water washing.

"N-GRIP (N-Grip) [for Equipment]" is a product that uses a mat made of GEL, which possesses both solid and liquid properties, enhanced with ultra-adhesiveness and ultra-low elasticity. It is easy to install and remove. It can be washed with water and reused multiple times. It does not damage the floor surface and can be used in a wide range of environments with an applicable temperature of -20°C to 75°C. The material is urethane elastomer with stainless steel fittings, and the average lifespan is about 10 years. [Features] ■ Easy to install and remove ■ Can be washed with water and reused ■ Does not damage the floor surface ■ Usable in a wide range of environments with an applicable temperature of -20°C to 75°C ■ Average lifespan of about 10 years *For more details, please refer to the PDF document or feel free to contact us.

  • 2022-08-01_16h49_55.png
  • 2022-08-01_16h50_12.png
  • 2022-08-01_16h50_31.png
  • 2022-08-01_16h51_48.png
  • 2022-08-01_16h51_54.png
  • 2022-08-01_16h52_01.png
  • 2022-08-01_16h52_12.png
  • 2022-08-01_16h52_23.png
  • Anti-vibration, earthquake-proof, vibration-isolating devices
  • Other environmental equipment
  • Other machine elements

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Current issues and proposed measures regarding displacement suppression at transformer terminal sections.

We will introduce seismic devices for transformers that significantly improve the seismic resilience of substation systems.

The "Transformer Seismic Isolation Device (TTR Type)" that we handle has various features, such as improving the rigidity of the distribution board without hindering the effects of the installed vibration isolation device and suppressing the relative displacement with the transformer. This document discusses the current seismic standards for building equipment and how to effectively and reliably suppress displacement, proposing and introducing the seismic isolation device for transformers (TTR Type). We invite you to read it. [Contents] ■ Current issues and proposed countermeasures ■ Features of the transformer seismic isolation device *For more details, please refer to the PDF document or feel free to contact us.

  • Anti-vibration, earthquake-proof, vibration-isolating devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Manufacturing Industry Business Improvement] Transformer Vibration Reduction Measures Version

Significantly reduces the displacement of transformer terminal sections due to seismic motion! Prevents large-scale power outages caused by transformer damage.

This catalog features products that are useful for vibration reduction measures for transformers as part of business improvement in the manufacturing industry. As a new proposal for BCP measures, we introduce the "TTR type" seismic isolation device for transformers. The catalog clearly presents the product features and importance, as well as verification results regarding the installation of this device, using diagrams and photos. Please use this for product selection. [Contents] ■ BCP Plan for Seismic Isolation Devices - Rapid operational recovery is essential for business continuity. - "Is an earthquake someone else's problem?" - The importance of transformers. - What are the verification results for the installation of this device? - Cubicle vibration reduction seismic isolation device. *For more details, please refer to the PDF document or feel free to contact us.

  • Anti-vibration, earthquake-proof, vibration-isolating devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Transformer Protection Often Overlooked in BCP Measures: Seismic Device for Transformers TTR

Seismic measures start with "transformers"! We achieve efficient disaster reduction measures (damage mitigation and early recovery).

The "TTR type" is a seismic device for transformers that significantly reduces the displacement of transformer terminal sections caused by large seismic motions, preventing large-scale power outages due to transformer damage. With the installation of TTR, a displacement of ±50mm or less at the terminal section has been achieved for all experimental seismic waves. Based on the building's response characteristics, it is possible to calculate and simulate the displacement of the transformer during an earthquake. In past earthquakes (such as in Eastern Japan and Kumamoto), the heaviest transformers in the cubicle were damaged, resulting in many cases where even if emergency generators were intact, electricity could not be extracted. Transformers are not readily available, meaning that operations would be suspended during that time. The TTR not only protects the transformer but also enhances the overall rigidity of the cubicle, contributing to the protection of various relays and LCBs. It enables efficient disaster reduction measures (damage mitigation and early recovery). 【Features】 ■ Significantly suppresses displacement caused by seismic motion with a special absorber at the top of the transformer ■ Effective against continuous earthquakes ■ Can be installed within the cubicle ■ Minimal changes to panel size due to TTR installation ■ Does not compromise the effectiveness of the installed vibration-damping device *For more details, please refer to the PDF document or feel free to contact us.

  • 2020-04-13_11h07_20.png
  • 2020-04-13_11h07_27.png
  • Anti-vibration, earthquake-proof, vibration-isolating devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Seismic Isolation Device 'N-Grip' <For Fixtures and Equipment> [Yamazen TFS]

Easy to install and remove! Usable in a wide range of environments with an applicable temperature of -20°C to 75°C.

"N-Grip" is a seismic device that uses a mat with gel that combines the properties of both solid and liquid, enhanced with ultra-adhesiveness and ultra-low elasticity. It allows for easy layout changes and enables design configurations that meet user requirements. It can also be used in wet areas. We offer options for both furniture and equipment, so please choose according to your needs. 【Features】 ■ Easy to install and remove ■ Does not damage the floor ■ Washable and reusable ■ Usable in a wide range of environments with an operating temperature of -20°C to 75°C ■ Average lifespan of 10 years *For more details, please refer to the PDF document or feel free to contact us.

  • Anti-vibration, earthquake-proof, vibration-isolating devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

"N-Grip Series" seismic resistance device for fixtures.

Custom designs that can respond to various sites are possible! Providing safety and peace of mind to protect people and equipment in preparation for sudden earthquakes.

The "N-Grip Series" is a seismic device that uses a mat made of GEL, which possesses both solid and liquid properties, enhanced with ultra-adhesiveness and ultra-low elasticity. It can be used in a wide range of environments with an operating temperature of -20°C to 75°C. Layout changes are easy, allowing for design configurations that meet user requirements, and it can also be used in wet areas. The standard types for fixtures include five types: "NLO, NRT, NRN, NXC, NPS," and the selection of fittings is made after assessing the items to be installed and the condition of the floor surface. 【Features】 ■ Easy to install and remove ■ Does not damage the floor surface ■ Can be reused by washing with water ■ Usable in a wide range of environments with an operating temperature of -20°C to 75°C ■ Average lifespan of 10 years *For more details, please refer to the PDF document or feel free to contact us.

  • Anti-vibration, earthquake-proof, vibration-isolating devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Manufacturing Industry Business Improvement: Trans Seismic Countermeasure Version

Significantly reduces the displacement of transformer terminal sections due to earthquakes! Prevents large-scale power outages caused by transformer damage.

Seismic vibration reduction and earthquake resistance measures for transformers are possible. We introduce the "TTR type" seismic isolation device for transformers as a new proposal for BCP measures. We have clearly presented the product's features, importance, and verification results regarding the installation of this device, using diagrams and photos. Please use this information for product selection. [Contents] ■ BCP plan for seismic isolation devices - Quick recovery of operations is essential for business continuity. - "Is an earthquake someone else's problem?" - The importance of transformers - What are the verification results for the installation of this device? - Cubicle vibration reduction and seismic isolation device *For more details, please refer to the PDF document or feel free to contact us.

  • Anti-vibration, earthquake-proof, vibration-isolating devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Power Supply BCP Measures: Seismic Device for Transformers 'TTR Type'

Seismic measures start with "transformers"! We achieve efficient disaster reduction measures (damage mitigation and early recovery).

The seismic isolation device "TTR type" significantly reduces the displacement of transformer terminal sections caused by large seismic motions, preventing large-scale power outages due to transformer damage. With the installation of TTR, a displacement of ±50mm or less at the terminal section has been achieved for all experimental seismic waves. Based on the building's response characteristics, it is possible to calculate and simulate the displacement of the transformer during an earthquake. In past earthquakes (such as those in Eastern Japan and Kumamoto), the heaviest transformers in the cubicles were damaged, resulting in many cases where emergency generators could not supply electricity even if they were intact. Transformers are not readily available, meaning that operations would be halted during that time. TTR not only protects the transformer but also enhances the overall rigidity of the cubicle, contributing to the protection of various relays and LCBs. TTR realizes efficient disaster mitigation measures. 【Features】 ■ Special absorbers at the top of the transformer significantly suppress displacement caused by seismic motions. ■ Effective even against continuous earthquakes. ■ Can be installed within the cubicle. ■ Minimal changes to panel size with TTR installation. ■ Does not compromise the effectiveness of the installed vibration isolation device. *For more details, please refer to the PDF document or feel free to contact us.

  • 2020-04-13_11h07_20.png
  • 2020-04-13_11h07_27.png
  • Anti-vibration, earthquake-proof, vibration-isolating devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

"Transformer Seismic Resistance: Even if the emergency power generation is safe, the transformer is important." TTR

Seismic measures start with "transformers"! We achieve efficient disaster reduction measures (damage mitigation and early recovery).

The seismic isolation device "TTR type" significantly reduces the displacement of transformer terminal sections caused by large seismic motions, preventing power outages due to damage at the terminal sections. With the installation of the TTR, a displacement of ±50mm or less at the terminal sections has been achieved for all experimental seismic waves. It is possible to calculate and simulate the displacement of transformers during earthquakes based on the building's response characteristics. In past earthquakes (such as those in Eastern Japan and Kumamoto), the heaviest transformers in substations were damaged, leading to many cases where electricity could not be extracted even if emergency generators were intact. Transformers are not readily available, meaning that operations would be halted during that time. The TTR not only protects the transformer but also enhances the overall rigidity of the substation, contributing to the protection of various relays and LCBs. It enables efficient disaster mitigation measures (damage reduction and early recovery). 【Features】 ■ Special absorbers at the top of the transformer significantly suppress displacement caused by seismic motions. ■ Effective against continuous earthquakes. ■ Can be installed within substations. ■ Minimal changes to panel size with TTR installation. ■ Does not compromise the effectiveness of the installed vibration isolation device. *For more details, please refer to the PDF document or feel free to contact us.

  • 2020-04-13_11h07_20.png
  • 2020-04-13_11h07_27.png
  • Anti-vibration, earthquake-proof, vibration-isolating devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.